Banco di carico del resistore da 500 kW
Banco di carico del gruppo elettrogeno trifase da 1KW a 500KW 1) L'utente può caricare qualsiasi potenza entro la potenz
Informazioni basilari.
Modello numero. | AC400-500KW |
Peso | 500 kg |
Volume | 1580 mm*1250 mm*1680 mm |
Controllo | Locale e remoto |
Resistore | Lega metallica |
Raffreddamento | Raffreddato ad aria |
PF | 1 |
Passo minimo | 1 kW |
Frequenza | 50Hz, 60Hz |
Energia | 500 kW |
Voltaggio | 380 V, 400 V, 415 V, 600 V, 690 V ecc. |
Pacchetto di trasporto | Scatola di legno |
Specifica | ISO |
Marchio | Carico di trionfo |
Origine | Cina |
Codice SA | 90303900 |
Capacità produttiva | 1000 set all'anno |
Descrizione del prodotto
1KW to 500KW 3 phase genset Load Bank 1) User could load any power within rated power, can test stable state three-phase voltage, current, active power, reactive power, apparent power, power factor, frequency, running time of generating set.2) Whether load/unload by manual control panel, remote control or by PC software control, user can pre-set the power then press the master load button.3) Control mode: user can choose local manual control, remote control or Intelligent control(PC control)3.1 Local manual control: there is local control panel in load bank, with multi load steps, min load steps 1kW, controlled by buttons.3.2 Remote control: remote controller connected the load bank with control cable.(optional)3.3 Intelligent control: user can control load bank by data processing software of PC to make automatic load/unload, display, record and manager the test data, form curve, graph and can be printed.4) Control mode interlock: there is switch in control panel to choose control mode, other control mode is invalid if user choose one control mode.5) With data processing software, could form curve of current, active power, reactive power, apparent power, power factor, frequency and can be printed.6) One-key load/unload: user can load or unload with one key easy to control.7) 3 line LED multi-function meter display.Protection of 1KW to 500KW 3 ph genset Load Bank 1) User can press the emergency stop button in the panel to unload immediately when the load bank is abnormal while working.2) Over-load: Automatic load dump and give alarm when voltage is over safety thresholds.3) Over-heat protection: Automatic load dump and give alarm when temperature is over safety thresholds.4) Short Circuit Protection: Fuse could avoids damage to equipment when short circuit or current overload.4) Fan protection: Machine could not do load testing before working power of fan is on.5) The machine will unload and give alarm when any fan is abnormal or with insufficient air volume, etc.6) When control power cable in wrong connections, 3 phase fans can also work in good conditions.7) Protection button: there are some protection buttons can be switched off when false alarm or for special requirements.Inviaci